» Single Zone Water Detection System: AquaTraq
AquaTraq water leak detection units were developed to provide great value single-zone
security against the ingress of water into areas housing
high-technology or high-value equipment and are supplied completely
ready for use. All they require is screw fixing to the wall, a local
power supply, and connection the sensor. AquaTraq Units can be
supplied with optional Battery Backup Pack for 10 hours operation
during a mains power failure.
AquaTraq Units operate on the proven Aqualeak principle of utilising
an AC field sensing signal to detect water and can monitor from the
full range of Aqualeak linear leak detection sensor cables, sensor
tape or from multiple water detection sensor probes, sensor pads,
overflow/level sensors etc.
Units have three levels of indication; ZONE HEALTHY, ZONE FAULT and
WATER DETECTED. An audible alarm is activated by any abnormal
condition and is silenced by pressing the mute button. The alarm is
designed to automatically reset, requiring no operator input, but
alarm lights remain on until the condition clears and this too
automatically resets when alarm clears.
The AquaTraq system has two sets of changeover alarm contacts. The
‘Alarm’ relay is for linking to an optional Aqualeak Remote
Alarm Unit or to link to a BMS system, to switch sump pumps or
solenoid valves, or to shut down process equipment or power supplies
etc. The 'Reset' relay can be used by the BMS to ‘time/date stamp’
when the mute button was pressed to indicate when the alarm was
acted upon, or to mute an external sounder.
The leader cable distance between the AquaTraq and the sensor/s, or
the maximum linear sensor cable sensing distance, should not exceed
50m. The AquaTraq System can also be linked to the optional Aqualeak
Automatic Telephone Dialling Unit which telephones remote addresses
to advise that the emergency has occurred.
|
 |
 |
 |
 |
|
 |
AquaTraq Units were specifically designed to operate with up to
50 metres of linear sensing cable , which is normally
installed in a computer room 'floor void', but have on-board
adjustment of detection sensitivity to allow monitoring
leaks from pads, probes and a number of other specialist
sensors, including wall-mounted probes, adjustable bund or
overflow sensors etc.
The detection sensor is connected to the AquaTraq by a 'leader cable'. This
enables the detection zone to be remote from the control unit to ensure the most effective
location of the unit relative to the sensor.
Click here to browse all of the compatible pads, probes
and cables.
|
|
|